Facilities

# Facility Specification Best suit for
1 Laser RAMAN Spectrometer Lab RAM HR (HORIBA) Laser: He-Ne (17mW) Wave length : 632.8 nm Microscope: Olympus optical microscope. Objectives: X10, X50, X100 Detector: CCD Illumination: 2 modes (transmission and reflection). Spectrometer : 2 gratings : 600 and 1800 Density Filters : To decrease the laser power liquid , powder, thin films
2 EDXRF Spectrometer Operating Parameters Voltage : 50KV ; Current : upto1 mA Elements : Na – U Detector Resolution: & emsp; 143 eV at 5.9keV; Detection limit : 1-10 ppm In air and in-vacuum measurements are feasible; Software – nEXT inbuilt. Contact Dr. Rajib Mondal
3 Micro EDXRF Micro EDXRF Contact Dr. Rajib Mondal
4 Tube Furance Maximum temperature 1400 degree centigrage Powder or pellet
5 Planetary Ball Mill It can be used in ambient as well as in an inert atmosphere. Powder
6 Vacuum Annealing Furnance Maximum temperature 1100 degree centigrade Pellet
7 15 Tesla cryogen free system with VSM, Resistivity, Dielectric, and Pyroelectric measurement options Having VSM (both dc magnetization and ac susceptibility), Resistivity, Dielectric and Pyroelectric measurement option Preferably in pellet form
8 4K CCR for zero field resistivity, dielectric and P-E loop measurement Resistivity, dielectric and P-E loop measurements in zero field. Temperature range:- 2.8-300 K Pellet or thin film
9 Tri-arc Furnace Maximum attainable temperature 3500 degree centigrade Powder form of the constituent elements are not preferred
10 Resistive Furnaces Maximum temperature 1600 degree centigrage Powder or pellet
11 Mössbauer Spectrometer Mossbauer spectra at room temperature for iron based samples Powder samples are preferred
12 High Temperature Furnace Heat treatment for materials at 1200 Degree Celsius in box furnace Powder, pellet, ingot, etc.
13 Ultrasonic Cleaner Ultrasonic cleaning of materials at room temperature and at elevated temperatures up to 80 degree Celsius, frequency 30 kHz, tank capacity 12 Litres Samples to be kept in a beaker